3 Stage Gearbox Supplier: Build a Sizing RFQ
Estimate speed, torque and heat loss, then export a supplier RFQ draft. Confirm product ratings before ordering.
By LowBacklashGearbox · Published 9 November 2026 · Reviewed
1. What to establish before selecting a supplier
| Decision | What is supported | Next action |
|---|---|---|
| Stage count | Ratio alone does not fix the number of stages; catalog families differ. | Request the exact model, ratio and stage count. |
| Backlash | Serial attenuation explains the equal-play illustration; it does not certify assembled accuracy. | Request a measured unit-level test at agreed conditions. |
| Continuous duty | Power loss estimates heat generation. Thermal capacity needs a separate heat balance. | Request application-specific continuous-duty evidence. |
| Interfaces | A dimensional interface standard does not establish load capacity. | Confirm the motor fit and actual radial, axial and moment loads. |
Basis: the tool equations below, Neugart PLE — product-specific ratio and stage data, ISO 1328-1:2013 — gear flank tolerance classification, ISO/TR 14179-1:2001 — thermal capacity reference conditions and ISO 9409-1:2004 — robot mechanical interface plates. No supplier is qualified or endorsed by this page.
2. Compare architectures against the application
This is a shortlist framework. Packaging and gear geometry suggest candidates; a product datasheet and application review establish suitability.
| Architecture | Candidate use | Checks before selection |
|---|---|---|
| Coaxial planetary | Compact motor-to-load alignment | Backlash, carrier stiffness, ratio availability and bearing loads |
| Inline helical | Industrial drives with space for a larger housing | Actual continuous thermal rating, mounting and lubrication |
| Bevel-planetary | Motor must turn through 90 degrees | Input bevel geometry, combined losses, noise and shaft alignment |
| Parallel spur | Simple gearing where packaging and noise allow | Measured noise, accuracy and full load spectrum |
| Two-stage alternative | Requested ratio is available in fewer stages | Compare efficiency, length, backlash and torque in the same duty |
Neugart PLE — product-specific ratio and stage data illustrates why ratios and stage counts should be read by product family. The tool accepts 40:1–1000:1 for calculation; that range is not a promise of catalog availability.
3. Reproduce the sizing method
| Quantity | Equation | Boundary |
|---|---|---|
| Output speed (rpm) | n_out = n_in / i | Exact nominal ratio; no transient acceleration |
| Required motor torque (Nm) | T_in = T_out / (i × η) | η is assumed overall efficiency; no starting or shock torque |
| Output power (kW) | P_out = T_out × n_out × 2π / 60000 | Mechanical output at the entered operating point |
| Heat generation (W) | P_loss = 1000 × P_out × (1/η − 1) | Not a temperature or cooling-capacity prediction |
| Reflected load inertia | J_ref = J_load / i² | Excludes gearbox inertia, compliance and control dynamics |
| Stage torque | T_k = T_(k+1) / (i_(k+1) × η_stage) | Equal η_stage = cube root of η; actual losses differ |
These are mechanical speed, torque and power identities with the stated assumptions, not a gear strength model. At the default 100:1, 450 Nm and 3000 rpm, output is 30 rpm, motor torque is 5 Nm and heat generation is about 157.1 W at 90% efficiency. The illustrative 4 × 5 × 5 split preserves the ratio; only tooth-count design can establish manufacturability.
4. Interpret backlash without overstating precision
For three serial stages, with each Δθ measured at its own stage output: Δθ_out ≈ Δθ₃ + Δθ₂/i₃ + Δθ₁/(i₂ × i₃). With equal intrinsic play and a 4 × 5 × 5 split, the weights are 0.04, 0.20 and 1.00: about 3.2%, 16.1% and 80.6% of the sum.
Different stage clearances change those percentages. Compliance under load, hysteresis and controller positioning error are separate quantities. A target in arcminutes is a requirement, not a computed product capability.
ISO 1328-1:2013 — gear flank tolerance classification concerns individual gear flank deviations. Ask for an assembled-unit backlash report with test torque, temperature, input restraint and direction reversal. P0/P1/P2 labels vary by supplier and are not used here as universal classes.
5. Audit material and geometry evidence
| Evidence | What to identify | What it does not prove |
|---|---|---|
| Material and heat treatment | Approved grade, delivery condition, heat/lot ID, case-depth and hardness requirements | A steel designation alone does not establish fatigue capacity |
| Gear inspection | Module, diameter, face width, measured deviations, standard edition and agreed class | One class does not mean the same micrometre limit for every gear |
| Carrier and housing CMM | Datum scheme, position/parallelism/runout tolerances from the drawing | One pin position number cannot determine mesh load sharing |
| Gear capacity calculation | Geometry, load spectrum, material condition and influence factors | A nominal output torque alone is insufficient to derive safety factors |
ISO 1328-1:2013 — gear flank tolerance classification and ISO 6336-1:2019 — gear capacity principles and influence factors provide the relevant classification and load-capacity scope. This page has not verified a supplier-specific tolerance budget or design calculation.
6. Separate bearing life from gearbox reliability
Basic roller-bearing rating life under constant load and speed is L10h = 10⁶/(60n) × (C/P)^(10/3), with C and P in matching load units and n as the applicable bearing rotational speed. Planet-bearing relative speed must be derived from the actual mechanism.
SKF — basic bearing rating life and ISO 281 model describes L10 as a 90% reliability measure and explains why lubrication and contamination change service life. It is not gearbox MTBF. This tool has no bearing selection, load geometry or relative speed input and therefore does not estimate bearing hours, Hertz stress or a life-limiting stage.
Ask for bearing part numbers, equivalent loads, relative speeds, lubrication assumptions and static checks at peak load. If those are unavailable, retain life as unknown before accepting a production design.
7. Qualify the supplier through five evidence gates
| Gate | Evidence | Hold point |
|---|---|---|
| 1. Application and design | Duty profile, load cases, exact ratio, motor and output drawings | Stop if ratings do not cover the entered operating envelope |
| 2. Process and metrology | Material/heat-treatment traceability and drawing-based inspection | Resolve missing acceptance limits before approving the sample |
| 3. Assembly | Lubrication, fill, cleanliness and seal controls | Confirm compatibility with orientation and environment |
| 4. Sample performance | Backlash, thermal, noise and applicable ingress evidence | Use agreed load, speed, test duration and pass criteria |
| 5. Batch release | Conformity, change control, lead time, warranty and spares | Resolve exclusions and inspection ownership in writing |
An ISO 9001, IATF 16949 or AS9100 certificate describes a management-system scope; it does not itself certify this gearbox rating. Check the certificate scope and agree product evidence separately. These gates are our proposed procurement method, not a standard-mandated certification sequence.
Export your RFQ and request these acceptance records
8. Heat generation is not thermal capacity
Two housings with identical calculated losses can reach different temperatures. Ambient, mounting conduction, exposed area, airflow, enclosure, lubricant and duty cycle determine heat rejection. The tool marks thermal capacity as NOT ASSESSED for every operating point.
ISO/TR 14179-1:2001 — thermal capacity reference conditions describes a mineral-oil heat-balance method with reference ambient and oil sump temperatures of 25°C and 95°C, plus modifiers. It does not create a universal 80°C or 85°C casing limit, nor a 150 W or 400 W cooling threshold. Grease-filled servo units and other conditions require product-specific evidence.
| Missing condition | Request from supplier | Decision use |
|---|---|---|
| Ambient, mounting and airflow | Thermal rating or equilibrium test for the installation | Confirm continuous operation without exceeding product limits |
| Lubricant and seals | Compatible product, viscosity/fill, temperature and maintenance limits | Avoid selecting grease/oil or seals from a generic rule |
| Cycle and transients | Cycle-average loss and peak torque/temperature checks | A lower average temperature does not permit unlimited peak torque |
9. Check interfaces and application mismatch
ISO 9409-1:2004 — robot mechanical interface plates defines an interface plate system without assigning load-carrying ranges. Confirm the actual allowable Fr, Fa and bending moment at the load location, plus coupling fit, motor pilot, insertion depth and fasteners.
A smooth shaft has no keyway: DIN 6885 key forms do not define it. Clamping and shrink-disc connections still need manufacturer torque, surface, fit and installation requirements. For a wheel or pulley with overhung load, attach the load-offset drawing; the tool cannot validate the bearings or shaft.
10. Worked RFQ examples — illustrative, not customer results
All three use assumed 90% overall efficiency, steady load and the same power equations. These are reproducible planning examples without verified product capacity, prices or field performance.
| Application and inputs | Calculated result | What must be verified |
|---|---|---|
| Servo rotary axis: 100:1, 450 Nm, 3000 rpm | 30 rpm output; 5.00 Nm motor torque; 157.1 W loss | Backlash at agreed torque, servo tuning, peak cycle and interface |
| Right-angle axis: 160:1, 800 Nm, 3000 rpm | 18.75 rpm output; 5.56 Nm motor torque; 174.5 W loss | Actual bevel ratio, combined efficiency and overhung loads |
| Continuous drive: 500:1, 4500 Nm, 1500 rpm | 3 rpm output; 10.00 Nm motor torque; 157.1 W loss | Continuous thermal rating, lubrication, starting torque and bearings |

Use the matching preset, compare the live output, then export the RFQ draft. A calculated operating point becomes a candidate only after supplier evidence covers the missing release conditions.
11. Compare costs and mitigate procurement risk
| Risk | Cost or failure exposure | Minimum mitigation |
|---|---|---|
| Misuse of estimates | Ordering a product against calculated torque without rating evidence | Hold purchase approval until duty, peak load and thermal checks pass |
| Scenario mismatch | A compact precision unit may not suit long continuous duty or wheel loads | Compare a larger housing, separate load bearing or alternate topology |
| Low quoted unit price | Tooling, qualification, shipping, spares and downtime may dominate | Compare identical quantities, tests and named delivery terms |
| Unverified savings | No quotes or comparable field data support a percentage saving | Mark price and downtime unknown until documented; use sensitivity ranges |
| Delivery responsibility | Customs, tax registration, carrier handover and claims may be unclear | Record the named place, rule, edition and responsible parties |
Use TCO = purchase + tooling + qualification + logistics/import charges + maintenance + expected downtime over a defined horizon. No market prices or supplier tiers are asserted here. For container and multimodal moves, ICC — Incoterms 2020 checklist, 2024 update supports considering FCA; FOB/CIF have a water-transport scope. Confirm jurisdiction-specific customs and tax execution separately.
12. Sources, date and known limitations
Source scopes and linked public guidance checked on . ISO catalog abstracts establish the listed scope; they do not substantiate product-specific tolerance values, bearing life, supplier pricing or universal thermal limits. Full standards and a qualified application review are required for design acceptance.
- ISO 1328-1:2013 — gear flank tolerance classification
- ISO 6336-1:2019 — gear capacity principles and influence factors
- ISO/TR 14179-1:2001 — thermal capacity reference conditions
- ISO 9409-1:2004 — robot mechanical interface plates
- SKF — basic bearing rating life and ISO 281 model
- ICC — Incoterms 2020 checklist, 2024 update
- Neugart PLE — product-specific ratio and stage data
Known: the entered operating point and the equations shown above. Assumed: overall efficiency, equal per-stage efficiency, illustrative ratios and equal intrinsic backlash. Unknown: tooth geometry, actual stage losses/play, housing heat transfer, load spectrum, bearing selection, seal compatibility, verified supplier capability, price and lead time. The target lead times are buyer requests, not delivery promises.
13. Questions before sending the RFQ
Sizing & model limits
Does a high ratio always require three stages?
No. Stage count depends on topology, tooth geometry and product family. Ask suppliers for the exact ratio and stage count; compare a two-stage alternative where available rather than applying a universal ratio cutoff.
What does this tool calculate?
Steady-state output speed, required input torque, mechanical power, heat generation and an illustrative three-stage split. It does not select a rated product or assess emergency torque, thermal capacity, fatigue life or safety.
Are the proposed stage ratios manufacturable?
Not necessarily. Their product matches the requested total ratio, but integer tooth counts, interference, planet spacing, strength and catalog availability still require supplier verification.
Why does Stage 3 have the largest backlash share?
The serial model divides upstream stage-output angular play by downstream ratios. The displayed percentages assume equal intrinsic play in all three stages. Actual assembled backlash must be measured and can have a different distribution.
Does a high ratio guarantee stable servo control?
No. Load inertia reflects through the ideal ratio squared, but gearbox inertia, compliance, friction, encoder location, resonances and controller tuning also affect stability.
Evidence & acceptance
Does an ISO 1328 accuracy grade guarantee assembled backlash?
No. It classifies individual gear flank deviations. Assembly clearances, bearings, housing and preload also matter. Agree an assembled-unit backlash test with torque, temperature and input-locking conditions.
Can carrier pin tolerance alone determine mesh load sharing?
No. Carrier and gear stiffness, errors, floating members, planet count and load all contribute. Ask for a design-specific load-sharing calculation rather than converting one position tolerance into a universal factor.
Is bearing L10 life the gearbox MTBF?
No. Basic rating life is a statistical rolling-bearing fatigue measure at 90% reliability. Gearbox service life also depends on gears, seals, lubrication, contamination, loading and assembly.
Thermal & interfaces
Can heat loss in watts predict a safe temperature?
No. Ambient temperature, housing heat transfer, mounting, airflow, duty and cooling are also needed. The tool therefore reports heat generation and marks thermal capacity as not assessed.
Does ISO/TR 14179-1 set a universal casing temperature limit?
No. Its stated reference heat-balance conditions include 25°C maximum ambient and 95°C oil sump temperature for mineral-oil gear drives, with modifiers for other conditions. These are not a universal casing, grease or seal limit.
Does an ISO 9409-1 flange establish moment capacity?
No. The standard addresses mechanical interface dimensions, designation and marking. The gearbox supplier must separately rate radial, axial and moment loads at the application load position.
Does a leak test prove IP65 or IP66 protection?
No. A production leak test can support process control, but the claimed ingress rating needs applicable dust and water test evidence for the actual enclosure and installation.
Commercial & next steps
How should I compare supplier prices?
Use the same ratio, duty, acceptance tests, quantity and named delivery place. Separate unit price, tooling, qualification, freight, import charges, spares and expected downtime. This page supplies a comparison method, not verified supplier quotes.
Which delivery rule should container shipments use?
Consider FCA at a named delivery point for container or multimodal transport. FOB and CIF are sea or inland-waterway rules. Confirm customs responsibilities and local feasibility with your logistics provider; DDP does not remove all execution risk.
What happens to my data when I use the tool?
Calculations and text exports run in your browser. Copy uses browser clipboard permission, download saves a text file, and the email link opens your mail client with a short summary. You choose whether to send and must attach the downloaded RFQ yourself.
What should I do if my application is outside the input range?
Do not clamp your requirement to the nearest allowed value. Send the actual torque, speed, ratio, cycle profile, environment and interface drawing for a manual supplier review. The input limits define this tool, not the limits of gearbox technology.
14. Complete the draft and request evidence
Add peak and emergency torque, cycle profile, ambient temperature, motor/output drawings, load position and required ingress rating. Agree test limits, named delivery place, quantity and warranty before comparing offers.
For an out-of-range application or incomplete specification, email [email protected] with the actual operating conditions. Feasibility, quotations and delivery dates require confirmation.